Art no: 2100 • Outdated

CO2 Alert Mk10 Sensor Add-on KIT

Art no: 2100 • Outdated

DISCONTINUED: The product has been replaced with CO2 Mk90 Sensor Add-on KIT (2119)

Mk10 CO2 Safety system
The Mk10 CO2 sensor is a stand-alone system that can be integrated with the Mk9 central unit and Mk9 CO2 sensor set, using the RS485 MODBUS communication protocol. Actually it can be connected to any other LogiCO2 safety product. This plug and play set contains a stainless-steel protection bar to protect the sensor. It also includes an additional warning Horn/Strobe.

The alarm levels can be changed to any level to comply with relevant standard or policy. All LogiCO2 sensors are automatically calibrated by the “ABC Algorithm”.

The pre-set alarm levels are:
5.000 ppm instantaneous Alert
5000 ppm TWA 8Hr (PEL)
1,5% (15.000 ppm) ½ STEL
3,0% (30.000 ppm) STEL

What is in the package?
CO2 Alert Mk10 with 5 m power/communication cable and 10 m signal cable + power supply + Protection bar + Horn/Strobe LED + 2 RJ45 1‐4 Connector + power supply + plug lock + manual + Alert + H/S sign

Specifications

CO2 Mk10
TECHNICAL DATA
Operating Principle: Non-dispersive infrared (NDIR)
Measurement range: 0.04 to 6,7% volume CO2
Accuracy: +/-0,02% volume CO2 + -5%
of reading
Operating temperature: 0 to 50°C (Sensor works from
-20°C but values valid only for
0-50 °C)
Operating humidity: 0-95% RH non condensed
Storage temperature: -40 to + 70 °C
Power supply: 24V DC ± 10%
Power consumption: 600 mA peak, 30 mA average
Serial communication: Modbus protocol over RS485
Output: Two 24 volt transistor outputs
Automatic calibration: 60 days
Weight: 400 grams
Dimension: Ø 90 mm, height 120 mm
Ingression protection: IP44

Manuals & instructions
English
English
Other languages
Spanish
French
Software